Filter Results By:

Products

Applications

Manufacturers

Current Meters

Measure current using either "Average responding" meters reading linear loads or "True RMS" meters measuring non linear loads.


Showing results: 451 - 465 of 489 items found.

  • Analog Sensors

    Solar Light Company Inc.

    Solar Light’s NIST-Traceable PMA-Series Analog Sensors represent the pinnacle of accuracy, durability, and selection on the market today. Our sensors measure discrete bands of the electromagnetic spectrum from the UVA, UVB, UVA+B, UVC, Visible Light, and Infrared regions. Both narrow and broad bands are available, to fit any application, including germicidal applications, environmental probes, and sensors for biologically weighted spectra (such as the erythema and CIE action spectra.) Over 135 different sensors are available in a variety of packages to fit any environment, from indoor clean rooms to harsh locations outdoors to 100 meters under water. Please note that Solar Light offers both Digital Sensors and Analog Sensors in the PMA-Series lineup. Select these Analog Sensors if you don’t need a digital display output of the reading, if you will be connecting to your own datalogger, or if you plan to use a voltage source to provide excitation voltage to the sensor and a digital volt or amp meter to read and convert the results. Analog Sensors are typically used as process sensors that are permanently installed to provide ongoing information. Typical current draw is under 1mA. (By contrast, Digital models are typically used as discrete sensors that are portable and located to provide short term information.)

  • 12 Function True RMS Professional MultiMeter + InfraRed Thermometer

    Extech EX470A - Extech Instruments Corporation

    The Extech EX470A True RMS Multimeter and Infrared Thermometer with Capacitance, Frequency, and Duty Cycle Measurements and 2 K-Type Remote Probes is the perfect meter for HVAC or plant maintenance. The IR thermometer measures the surface temperature from -4 to 518 °F (-20 to 270 °C) without contact. The built-in laser pointer centers the measuring area. Multimeter functions include AC and DC Voltage to 600 Volt, AC and DC current to 10A, resistance to 40MOhm, continuity and diode test. Also includes Type K thermometer for contact or air temperature measurements from -4 to 1832 °F (-20 to 750 °C). Advanced functions include Capacitance, Frequency and Duty Cycle. The meter comes complete with test leads, Type K temperature probe, 9 Volt battery, protective holster, adjustable tilt stand and Velcro hanging strap.

  • Bench Digital Multimeter, Calibrated, 1 kV, 10 A, 3.8 Digit

    72-1015 CAL - Tenma

    The 72-1015 CAL from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.

  • Bench Digital Multimeter, Calibrated, Data, 1 kV, 10 A, 3.8 Digit

    72-1015 CAL D - Tenma

    The 72-1015 CAL D from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.

  • Bench Digital Multimeter, Calibrated D & U, 1 kV, 10 A, 3.8 Digit

    72-1015 CAL DU - Tenma

    The 72-1015 CAL DU from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.

  • Bench/System Multi-Range DC Power Supply With Digital Control, 3 Or 4 Outputs, 315 To 420W With/without Remote Interfaces

    MX Series - Aim-TTi

    Three or four high performance outputs each with full functionalityRange switching gives variable voltage/current combinationsShared power mode provides double power from a single outputLow output noise and ripple via linear final regulationHigh setting resolution of up to 1mV and 0.1mAVariable OVP and OCP trips on all outputs50 setting memories per output plus 50 linked memoriesSelectable voltage tracking (isolated tracking)Selectable current meter averagingSwitchable remote sense capabilityGraphic LCD provides simultaneous output meteringNumeric or spin-wheel control of all parametersIndividual or combined output on/off control with programmable delay sequencing.3U half-rack case for bench or rack mounting (4U rack kit accessory available)RS-232, USB and LAN (LXI) interfaces (P models)GPIB option (P models only)Duplicate power & sense terminals at rear (P models)

  • High Voltage EMC Surge Generator

    TM510 - T&M Tools Limited Co

    TM510 Surge Generator is mainly used for testing power cable high-resistance and arc-over fault whose grade range is 0-10kV, co-operating with cable fault tester and locating devices to test and locate faults. If the user choose the professional digital milli-ampere-meter, as for cable with grade range about 0- 6kV, the instrument can also be used to do DC&voltage resistance test and current leakage test after the fault is repaired. The instrument is internally equipped with voltage-rise rectifying and discharging device, has complete functions, and is also convenient and safe to be wired and operated.

  • AC Line Splitter

    Extech 480172 - Extech Instruments Corporation

    This Extech 480172 Line Splitter provides a fast and easy way to “open” standard 120 Volt AC electrical lines, eliminating the need to cut off the plug and separate the conductors. When connected between a 120 Volt AC outlet and a device under test, this splitter separates the hot/live conductor from the neutral and ground, which enables users to measure AC current up to 15 Amp on a two-wire or three-wire lines using a clamp meter. This splitter also features two Voltage Test jacks so that voltage can be measured using a multimeter.

  • 1000A True RMS AC/DC Clamp Meter with IR Thermometer

    Extech EX830 - Extech Instruments Corporation

    The EX830 clamp meter features a unique, built-in, non-contact Infrared thermometer with laser pointer to monitor temperature and locate hot spots on motors and electrical devices. A large 4000 count LCD display with bright back lighting allows you to see the reading in dim light. The ergonomically designed double-molded housing offers a better grip for one-hand operation. The 1.7" (43 mm) diameter jaw opening is large enough for conductors up to 750MCM. In addition to AC/DC current, it measures AC/DC voltage, resistance, temperature, capacitance, and frequency. It features: diode test, audible continuity beeper, min/max, data hold, auto power off, and a fast peak hold that captures inrush currents and transients. Comes complete with test leads, 9V battery, type K bead wire temperature probe (-4 to 482°F/-20 to 250°C) and a belt holster.

  • Transformer Turns Ratio Meter

    TTRM 302 - Scope T&M Pvt, Ltd.

    SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.

  • Transformer Turns Ratio Meter

    TTRM 301 - Scope T&M Pvt, Ltd.

    SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.

  • 400A Dual Input AC/DC Clamp Meter + NCV + IR Thermometer

    Extech EX623 - Extech Instruments Corporation

    This TRMS AC/DC Clamp Meter has dual thermocouple inputs for T1, T2, T1-T2 Differential Temperature measurement plus a built-in Infrared Thermometer with laser pointer for locating hot spots and NCV Detector. Additional features include: DC micro-amp function for flame rod measurements, Diode open circuit voltage of 2.8 Volt, Data Hold plus fast Peak Hold for capturing current surges at motor startup, and capacitance measurement to 40mF. Comes complete with test leads, 9 Volt battery, two Type K bead wire Temperature probes and carrying case.

  • Multifunctional Meter

    CPM-80 - Chuan Sheng Electronics Co., Ltd.

    CPM-80 multifunction power analyzer provide high accuracy single phase and three-phase energy measuring and displaying, energy accumulating, power quality analysis, data logging and data communication. CPM-80 series meters are able to measure bidirectional, four quadrants kWh and kVarh. It provides maximum/minimum records for power usage and power demand parameters. Hardware standard built in a RS485 Modbus communication port , 4 Digital inputs, 2 Relay outputs, LCM and 2MB flash for data-logging. In addition , also provide TOU , voltage and current THD, harmonics up to the 63rd and auto wiring change via software .

  • Thermitest

    THW-L2 - Thermtest Instruments

    Designed with speed and operational simplicity in mind, the Transient Hot Wire (THW-L2) Liquid Thermal Conductivity Meter is an advanced measurement system for direct determination of the thermal conductivity of liquids and pastes in accordance with ASTM D7896-19. In less than 2 seconds, a single measurement of small volumes of liquids and pastes can be accurately and precisely measured for thermal conductivity. Using a non-stationary measurement approach, the THW-L2 uses rapid test times to limit convective effects for samples with a wide range of viscosities. The THW sensor consists of a 60 mm heating wire that is fully inserted into an isothermal sample. A constant current source (q) is used to heat the sensor wire and the temperature rise is recorded by monitoring the change in electrical resistance of the wire. The slope (m) is determined from the plot of temperature rise vs. logarithm of time and is used in the calculation of thermal conductivity (λ). Liquid samples of high thermal conductivity will have a lower slope, while liquid samples with low thermal conductivity will have a higher slope.

  • LED Driver Aging Rack

    LEDRACK-100W192P - Lisun Electronics Inc.

    • Application range: LED driver and multi channel driver power aging. It has equipped with computer operation and monitor system. The working condition can be set by the computer, and the computer will record real time data to do statistical analysis. • The parameters of load can be set freely on the software, to monitor the real time voltage, current, and power etc • Load mode: CC, CV, CR, CP, and LED • Aging Control System includes: ON/OFF control signal output; Signal of relay switch control; K type thermocouple temperature acquisition • The channels are parallel connected under arbitrary load mode, which can allow product power expansion • The LED Driver Aging rack will design according to customer’s LED driver power and aging quantity per time • Automatic current switching function (optional) • AC power meter to measure modules, and test power input characteristics (optional) • Temperature monitoring function at product zone (optional) • PWM dimming and two sets of logic control signal function (optional)